Trevor Suslow |
|
Dept. of Vegetable Crops |
|
University of California, Davis |
|
|
|
|
|
|
The Standard Operating Procedure (SOPs) for
cleaning and sanitation should be documented, and should include: |
|
|
|
Cleaning and sanitizing schedule |
|
Name
and type of cleansers to be used |
|
Cleaning instructions, including a |
|
cleanser
– rinse - sanitizer sequence |
|
|
|
|
These areas should be replaced, repaired or
meticulously cleaned as appropriate |
|
Cracked
hoses |
|
Hollow
framework |
|
Poorly-maintained filters |
|
Standing water |
|
Open
bearings |
|
Porous
surfaces – ex. wood |
|
|
|
|
|
|
Condensate; especially walls and pipes over
packing lines |
|
Damp insulation |
|
Rubber seals around doors |
|
Light switches |
|
Cleaning tools |
|
Trash cans |
|
Icemakers |
|
|
|
|
|
|
|
|
The type of cleanser chosen should depend on
the particular operation.
Packer/Shippers should evaluate their cleaning needs and choose a
cleanser with input from a reputable supplier |
|
|
|
|
|
|
Be sure to follow all label instructions |
|
|
|
Strong
alkaline |
|
Heavy soils, not effective on mineral
deposits |
|
Heavy
duty alkaline |
|
For removal of oils/waxes, not effective
on mineral deposits |
|
Mild
alkaline |
|
Good for water softening and removal of light soil, not
effective on mineral deposits |
|
|
|
|
Strong
acid |
|
removal of mineral scale, encrusted soil |
|
Solvent
cleanser |
|
removes petroleum-based soil, grease |
|
Synthetic
detergents |
|
best on fats, oils and greases |
|
|
|
|
Quaternary ammonium |
|
- sanitize the cold room facility |
|
- effective against Listeria monocytogenes |
|
|
|
|
Weekly procedures should include the walls,
ceiling, floors, drains, equipment |
|
|
|
Cooling units should be cleaned semi-annually
according to the manufacturer’s instructions |
|
|
|
Coolers should be emptied, cleaned, rinsed and
sanitized at least once a season |
|
|
|
|
Clean drains with cleanser and brushes small
enough to clean effectively |
|
|
|
Ceiling, walls and floors should be rinsed from
top, downward |
|
|
|
|
|
|
Cold room should be emptied |
|
equipment should be cleaned |
|
outside of cold room facility |
|
|
|
Dry-clean by carefully sweeping floors |
|
|
|
Apply cleanser to walls, ceiling and floors |
|
|
|
Scrub area from top to bottom |
|
use cleaning utensils that are |
|
exclusively for cleaning the cold room |
|
|
|
|
Sanitizer should be applied to surfaces: |
|
Apply a high level sanitizer (800 ppm Quat) |
|
Let stand for 20 minutes |
|
Rinse |
|
Apply regular level sanitizer (200 ppm quat) |
|
Rinse |
|
Dry floors |
|
Clean and put away supplies |
|
|
|
|
|
|
Clean
and Sanitized |
|
outside the cold room |
|
|
|
Food
contact surfaces and utensils |
|
never touch the floor !!!!! |
|
|
|
|
Pre-rinse equipment |
|
Visually inspect equipment surfaces |
|
Apply appropriate cleanser |
|
scrub from top, downward |
|
Do not allow cleanser to dry on surfaces |
|
Rinse from top, downward |
|
|
|
|
|
|
Visually inspect equipment surfaces |
|
Sanitize surfaces |
|
apply high level sanitizer (800 ppm
quat) |
|
Let stand for 20 minutes |
|
Rinse – potable water |
|
Secondary sanitizer |
|
apply regular level sanitizer (200 pppm
quat) |
|
Rinse – potable water |
|
|
|
|
Clean and put away supplies |
|
|
|
Document cleaning |
|
|
|
Periodic QA inspection/swabs |
|
|
|
Training |
|
|
|
|
|
|
|
|
Product flow should be linear |
|
|
|
Don’t mix packed and ungraded |
|
|
|
No access from field to catwalks |
|
|
|
Bin and tote sanitation |
|
|
|
|
|